Loading

ALTERNATING CURRENT FIELD MEASUREMENT

Crack and material-condition detection at and near the surface — MT, PT, ET, ACFM, roughness and hardness.

Machinist measuring a threaded steel part on a spinning lathe

ACFM is used for detecting and sizing surface breaking flaws. ACFM is also applied to structures both in and out of the water. (It has the advantage over some other techniques that the structure requires minimal cleaning and that it can be applied over paint and other coatings up to several millimetres in thickness).

ACFM is an electromagnetic technique. A sensor probe is placed on the surface to be inspected and an alternating current is induced into the surface. When no defects are present the alternating current produces a uniform magnetic field above the surface. Any defect present will perturb the current, forcing it to flow around and underneath the defect; this causes the magnetic field to become non-uniform and sensors in the ACFM probe measure these field variations.

Two components of this magnetic field are measured – one provides information about the depth or aspect ratio of the defect(s), and the other shows the positions of the defects’ ends. The two signals are used to confirm the presence of a defect and, together with a sizing algorithm, measure its length and depth.

The advantages of ACFM are that it:

  • Works equally well on parent material or welds, ferritic or non-ferritic metals.
  • Can be used on hot surfaces, underwater, or in irradiated environments.
  • Provides both depth and length information. Defects up to 25mm (1″) in depth can be sized accurately.

Applications

  • Detection and sizing of fatigue cracks and hydrogen cracking
  • Inspection of fillet welds in mobile offshore drilling Units
  • Inspection of fillet welds in highway bridges
  • Inspection of rail components
  • Inspection of gear box, gear teeth, crank shafts, cylinder heads, turbines etc. in aerospace industries
  • Detection of cracks and corrosion in vessels, storage tanks and piping in oil & gas and power generation industries
  • Inspection of drilling tools
  • Inspection of various components in automotive industries

Technical image gallery for ALTERNATING CURRENT FIELD MEASUREMENT

NDT Level II Training & Certification for ALTERNATING CURRENT FIELD MEASUREMENT

What is ACFM Testing?

Alternating Current Field Measurement or ACFM is an electromagnetic inspection technique that introduces an alternating current into the surface of the component to detect surface-breaking cracks.

The presence of a crack disturbs the electromagnetic field and the return signal is instantaneously converted by advanced mathematical techniques, so that the operator is alerted to the presence of a defect. Immediate defect sizing and recording is a major benefit compared to alternative NDT methods.

What does a certified ACFM Level 2 inspector do?

An individual certified to ACFM Level 2 has demonstrated competence to perform NDT according to ACFM procedures. Within the scope of the competence defined on the certificate, Level 2 personnel may be authorised by the employer to:

  • Select the ACFM technique for the test method to be used
  • Define the limitations of application of the testing method
  • Translate NDT codes, standards, specifications and procedures into NDT instructions adapted to the actual working conditions
  • Set up and verify equipment settings
  • Perform and supervise tests
  • Interpret and evaluate results according to applicable standards, codes, specifications or procedures
  • Prepare ACFM written instructions
  • Carry out and supervise all tasks at or below level 2
  • Provide guidance for personnel at or below level 2
  • Report the results of ACFM test
  • Carry out and supervise all tasks at or below level 2
  • Provide guidance for personnel at or below level 2

Training

80 hrs of ACFM Level II training covers the following:

General Theory

  • History of electromagnetic testing
  • Terms and definitions used in electromagnetic testing
  • General principles of the ACFM technique
  • Electrical Theory. Further principles of AC theory
  • Equipment – ACFM equipment design and construction

Sector Specific Theory

  • Introduction to the range of available ACFM techniques
  • Types of equipment: Equipment selection and preparation
  • The effect of the ACFM test on the material to be tested
  • Preparation for testing
  • Carrying out the test
  • Post-test procedures reporting
  • Codes, standards and specifications
  • Briefing of remote probe operator
  • Surface preparation
  • ACFM techniques
  • Safety precautions, fire hazards, electrical safety
  • Conduct of test
  • Test procedure
  • Factors affecting the sensitivity of the ACFM technique
  • Probe and instrument set-up
  • Computer file handling
  • Detectability of defects
  • Characterisation of defects
  • Interpretation and reporting
  • Types of discontinuity and their identification
  • Responsibilities for reporting
  • Welding product technology
  • How defects are formed

Learn more about our NDT training & certification →