PENETRANT TESTING
Crack and material-condition detection at and near the surface — MT, PT, ET, ACFM, roughness and hardness.

Penetrant testing – Based on the properties of capillary action, or the phenomenon of a liquid rising or climbing when confined to a small opening due to surface wetting properties of the liquid, Penetrant testing is used for finding surface breaking discontinuities on relatively smooth, nonporous surfaces.
The types of defects that can be found with Penetrant inspection are:
- Rolled Products: Penetrant identifies anomalies (cracks, seams or laminations)
- Castings: cold shuts, hot tears, porosity, blow holes or shrinkage
- Forgings: Illuminating cracks, laps or external bursts
- Welds: To identify cracks, porosity, undercut, overlap, lack of fusion or lack of penetration.
There are two main types of Penetrant, Fluorescent or Visible. Within each method there are several methods including water washable, postemulsifiable-lipophilic, solvent removal and postemulsifiable-hyperdrophilic. The type and penetrant method are chosen based on sensitivity levels 1-4 and are based on job site conditions and other variables.
The main advantages of Penetrant testing are:
- Relatively easy to use
- Used on a wide range of material types
- Large areas or large volumes of parts/material can be inspected rapidly and at low cost
- Parts with complex geometries can be inspected easily
- Indications are produced directly on the surface of the part providing a visual image of the anomaly
- Aerosol spray cans can make equipment very portable
Technical image gallery for PENETRANT TESTING
NDT Level II Training & Certification for PENETRANT TESTING
What is Penetrant Testing?
Penetrant Testing involves applying a visible or fluorescent dye to the surface. The dye enters the discontinuities via capillary action. The method can be applied to any non-absorbent material with uncoated surfaces.
What does a certified Penetrant Level II inspector do?
An individual certified to Penetrant testing Level II has demonstrated competence to perform NDT according to Penetrant Testing procedures. Within the scope of the competence defined on the certificate, Level II personnel may be authorised by the employer to:
- Select the Penetrant technique for the test method to be used
- Define the limitations of application of the testing method
- Translate NDT codes, standards, specifications and procedures into NDT instructions adapted to the actual working conditions
- Set up and verify equipment settings
- Perform and supervise tests
- Interpret and evaluate results according to applicable standards, codes, specifications or procedures
- Prepare Penetrant written instructions
- Carry out and supervise all tasks at or below level 2
- Provide guidance for personnel at or below level 2
- Report the results of Penetrant test
Training
12 hrs of Penetrant testing Level II training covers the following:
General Theory
- Introduction
- Principles of penetrant inspection
- Equipment
- Preparation for testing
- Testing techniques
- Post test procedures
- Safety precautions
- Processing
- Testing procedures and selection
- Product technology
- Inspection and evaluation
- Interpretation and reporting
Specific Theory — Application of the Method to the Specific requirements of the Company, in particular making reference to those Codes, Specifications and Procedures used by the Company, including the relevant control checks.
IEQS Technologies have their NDT Training institute at Chennai, Mumbai, Kochi and Vizag. For NDT Training course & certification fees or Price details, please visit our website. IEQS Technologies assist or assure NDT placement for successfully completed Level II candidates.
Related services for PENETRANT TESTING

Magnetic Particle Testing (MT)
Crack and material-condition detection at and near the surface — MT, PT, ET, ACFM, roughness and hardness.
Read method & view details
Eddy Current Testing (ET)
Crack and material-condition detection at and near the surface — MT, PT, ET, ACFM, roughness and hardness.
Read method & view details
ACFM
Crack and material-condition detection at and near the surface — MT, PT, ET, ACFM, roughness and hardness.
Read method & view detailsEngage IEQS for PENETRANT TESTING
Tell us the standard, scope and schedule for your inspection and we'll come back with a tailored quote.